Description
DIMENSIONS: 66.0mm x 88.0mm (top panel)
MAIN FEATURE
Stainless steel fascia and key-tops guard willful destruction, against corrosion, shock, dust, falling raining, splashing, hose-directed water and vandal resistant, operation under hostile environments.
key-tops are sunk laser-etched in legends and characters via using high quality ink for easy readability, long life to prevent lettering rub-off.
With firm tactile key feel, full long carbon-on-gold key switches, with unique double over-travel protection.
Waterproof/dirt-proof execution according to degree of protection IP67, waterproof and dirt proof encapsulation with unique membrane.
Easily mounting into enclosure or panel, and is provided with PS/2, USB or RS232, connection output cables that plug directly into the host computer for keypad operations.
OS: All Windows, Linux, Unix, Mac OSX, Vxworks, Android, (U-cos–To be confirmed)
MECHANICAL DATA
Switching material: Carbon-on-Gold
Actuation Force: 0.6 N+/-0.1N for key 14.0mm x 14.0mm (pressure point)
Key Travel: 2.0mm
Lettering: laser engraving, or raised letters.
Front panel: brushed stainless steel
Actuator/keys materials: brushed stainless steel
Dimensions: 66.0mm x 88.0mm (top panel)
G.W. 0.4 KGs
ELECTRICAL DATA
Power supply voltage: 5V DC.
Power Consumption: Under 30mA for operation
Electrical lifetime: > 5 years
EMC Standard: It is compliance with the council IEC 61000-4-2:2008; IEC 61000-4-3:2006+AI:2007+A2:2010; IEC 61000-4-4:2004
EMI: EN 55022: 2010
EMS: EN 55024:2010
Communication interface: PS2, USB or RS232 are all available.
ENVIRONMENTAL ADAPTABILITY
Operating temperature:-20℃ to +60℃
Storage temperature: -30℃ to +70℃
Operating RH: 30-90%
Atmospheric pressure: 60-106Kpa.
Saline mist: 96 hours, IEC 60512-6
Damp heat test at + 40℃: 21 days, IEC 60512-6
Dry heat test at + 85℃: 10 days, IEC 60512-6
RELIABILITY
RoHS Compliant, CE and FCC
Protection Level: IP67(front panel)
Vandal resistant IK09
Key Lifespan >10 million actuations
MTBF >50000H
MTTR <30min