R15ID3S-65EX

15 tum, upplösning: 1024×768, Kontrast: 700:1, Ljusstyrka: 550

Processor: Intel® Atom Dual Core N2600

Description

Produktblad R15ID3S-65EX

Features

‧This Equipment is ATEX Zone 2 certified for Hazardous area applications and suitable for use in Class I, Division 2, Hazardous area
‧Wide power input 9-36V DC with isolation protection
‧Special IP65 connectors with cover plate
‧Designed with NEMA 4 (IP65) dust proof and water protection
‧Robust and fanless design for reliable operation
‧Fanless Cooling System and Ultra Low power consumption
‧Support Intel Atom N2600 processor
‧ELO 5W Resistive Touch ( Explosion-proof )

LCD Panel Specification

Size15″
Active Display Area304.1 (H) x 228.1 (V)
Pixel Pitch0.297 (H) x 0.297 (V)
Resolution1024 x 768
Contrast Ratio700:1 (typ.)
Display Color16.2M (6 bits + FRC)
Brightness550 (typ.)
Viewing Angle-80~80 (H); -70~70 (V)
Recommend Resolution1024 x 768@60Hz, 75Hz
Power ManagementVESA DPMS Compliant
Plug PlayVESA DDC 1/2B
Touch Sensor Type5-Wire Resistive

System Specification

FormFactor3.5″
Processor SocketOnboard
ProcessorIntel® Atom Dual Core N2600 1.6GHz
ChipsetIntel® NM10
Memory1 x DDR3 SO-DIMM 1333 MHz (default 4GB)
BIOSAMI 16 Mbit Flash
VGA ControllerIntegrated Graphics
LCD Support24 bit single-channel LVDS
EthernetDual Broadcom BCM57780 GbE controller
AudioRealtek ALC886 HD Audio Codec
SATA1 x SATA II
Serial1 x RS-232,1 x RS-232/422/485(Optional)*
USB2 x USB
Watchdog Timer256 Levels
Expansion Slots1 x Mini PCI (internal)
StoragemSATA SSD (default 64GB, option up to 128GB)
OSWindows Embedded Standard 7 Windows 7 Pro for Embedded Systems
Power AdapterDC IN 12V
EnvironmentEnvironment & Dimensions
TemperatureOperating: -10°C to +50°C
Humidity10% to 95% (non-condensing)
CoolingFanless cooling concept
ShockMIL-STD-810F/G Method 516.6
VibrationMIL-STD-810F/G Method 514.6Packing:: 5 Hz ~ 500 Hz/ 2.16 Grms/ 3 Axis

I/O Connectors

Back Panel I/O Port
  • 1 x COM
  • 1 x LAN
  • 2 x USB
  • 1 x Power input

Standard and Certification

Certification
  • UL60950-1, CSA C22.2 No. 60950-1-07, EN60950-1, IEC60950-1
  • ATEX zone 2 EX II 3 G Ex ic nA IIC Gc
  • UL Class I, Div.2, Groups ABCD T4 ANSI/ISA12.12.01 CAN/CSA C22.2 No. 213-M1987
  • Note: All Specifications are subject to change without prior notice!
    *If you use SBC on-board RS485, you need to set appropriate state of RTS line before sending/receiving data in your software program.We offer additional board that can perform auto-direction hardware function.

 

 

Kategori: Panel PC, Brandfarliga Miljöer